Monday, March 30, 2009

Evaporator Types and Applications

Evaporators are often classified as follows:
  1. heating medium separated from evaporating liquid by tubular heating surfaces,
  2. heating medium confined by coils, jackets, double walls, flat plates, etc.,
  3. heating medium brought into direct contact with evaporating liquid, and
  4. heating with solar radiation.


Evaporators with tubular heating surfaces dominate the field. Circulation of the liquid past the surface may be induced by boiling (natural circulation) or by mechanical methods (forced circulation). In forced circulation, boiling may or may not occur on the heating surface

Solar evaporators require tremendous land areas and a relatively cheap raw material, since pond leakage may be appreciable. Solar evaporation generally is feasible only for the evaporation of natural brines, and then only when the water vapor is evaporated into the atmosphere and is not recovered.

Evaporators may be operated batchwise or continuously. Most evaporator systems are designed for continuous operation. Batch operation is sometimes employed when small amounts must be evaporated. Batch operation generally requires more energy than continuous operation.

Batch evaporators, strictly speaking, are operated such that filling, evaporating, and emptying are consecutive steps. This method of evaporation requires that the body be large enough to hold the entire charge of the feed and the heating element be placed low enough not to be uncovered when the volume is reduced to that of the product. Batch operation may be used for small systems, for products that require large residence times, or for products that are difficult to handle.

A more frequent method of operation is semibatch in which feed is continuously added to maintain a constant liquid level until the entire charge reaches the final concentration. Continuous-batch evaporators usually have a continuous feed, and over at least part of the cycle, a continuous discharge. One method of operation is to circulate from a storage tank to the evaporator and back until the entire tank is at a specified concentration and then finish the evaporation in batches.

Continuous evaporators have continuous feed and discharge. Concentrations of both feed and discharge remain constant during operation.

Evaporators may be operated either as once-through units or the liquid may be recirculated through the heating element. In once-through operation all the evaporation is accomplished in a single pass. The ratio of evaporation to feed is limited in single-pass operation; single-pass evaporators are well adapted to multiple-effect operation permitting the total concentration of the liquid to be achieved over several effects. Agitated-film evaporators are also frequently operated once through. Once-through evaporators are also frequently required when handling heat-sensitive materials.

Recirculated systems require that a pool of liquid be held within the equipment. Feed mixes with the pooled liquid and the mixture circulates across the heating element. Only part of the liquid is vaporized in each pass across the heating element; unevaporated liquid is returned to the pool. All the liquor in the pool is therefore at the maximum concentration. Recirculated systems are therefore not well suited for evaporating heat sensitive materials. Recirculated evaporators, however, can operate over a wide range of concentration and are well adapted to single-effect evaporation.

There is no single type of evaporator which is satisfactory for all conditions. It is for this reason that there are many varied types and designs. Several factors determine the application of a particular type for a specific evaporation result. The following sections will describe the various types of evaporators in use today and will discuss applications for which each design is best adapted.

Sunday, March 29, 2009

Mechanisms Flow-Induced Vibration

Induced vibration of any system involves the coupling of some exciting forces with an elastic structure. In the case of flow-induced vibration, the exciting forces result from the flow of the shellside fluid and the elastic structure in the bundle of tubes. The exciting forces fluctuate at characteristic frequencies which increase continuously with increasing flow rate. The tubes vibrate only at unique responding frequencies called their natural frequencies. Coupling occurs when the exciting frequencies match the responding frequencies and tube vibration results.

The natural frequency of tubes depends primarily on their geometry and material of construction. The intensity of vibration is evidenced by the amount of periodic movement; the extent of this peak-to-peak movement about the at-rest centerline is termed the amplitude of vibration. Energy must be available to excite the tubes into vibration. The energy of vibration is dissipated by internal and external damping. The exciting force could be the result of:
  1. fluid dynamic mechanisms as a result of flow parallel to or across the tubes
  2. pulsations of a compressor or pump
  3. mechanical vibrations transmitted through a structure.
Unless amplified by resonant phenomena, the flow forces normally enountered in equipment are not sufficient to cause damage. Resonance, which can increase the tube deflection by orders of magnitude, occurs when the frequency of a cyclic exciting force coincides with the natural frequency of the tube

In order to predict the occurrence of flow-induced vibration, the phenomena that produces the exciting forces and the dynamic response by the tubes must be understood. The determination of tube natural frequencies is relatively straight-forward. However, determination of the exciting forces created by the shellside fluid flow is extremely more difficult. The shellside flow in a heat exchanger follows a complex flow path. It is subjected to changes of direction, acceleration, and deceleration. At times, the flow is either perpendicular to the tubes (crossflow), axially along the tubes (parallel flow), or at any angle in between. Flow phenomena in crossflow include vortex shedding, turbulent buffeting, and fluid-elastic whirling, The flow phenomena found in parallel flow includesaxial-flow eddy formation.

Saturday, March 28, 2009

Flow-Induced Vibration in Evaporations

The concern for flow-induced tube vibration has become a serious consideration in the design of shell-and-tube equipment. These problems can lead to tubes and tubejoints that leak, increased shellside pressure drop, and intolerably loud noises. The result is that equipment must be removed from service for repair and modification.

Flow-induced vibrations can damage tubes in evaporators. All tubes vibrate under all flow conditions! However, we are concerned with vibrations which cause significant tube damage. As larger evaporators, greater flowrates and higher shellside velocities become more prevalent, damaging tube vibrations are more likely to occur. No evaporator design is complete without considering the possibility of damage as a result of flow-induced vibrations.

Damage is more likely to occur with gases or vapors on the shellside than with liquids. Flow-induced vibrations also occur with liquids on the shellside, but the damage is often limited to localized areas of relatively high velocity. In severe cases, tubes can leak within a few days or even in a few hours after the equipment has been placed in service. More often, damage will appear a year or so after startup. Additional tube damage will develop after the initial damage has been repaired, but the number and frequency of further damages will decrease with time.

In a number of cases, heat exchanger tube failures attributed to flowinduced vibration have resulted in consequential damage to other equipment within a plant. Failures of this nature have proven to be the most destructive, most costly, and have required the longest plant shutdowns for rectification.

Currently available methods for predicting flow-induced vibration damage are inadequate for predicting failures. At best, they identify the equipment that are susceptible to damage. The primary reason for this lack of precision is that flow-induced vibrations are extremely complicated. Much has been learned, but the probability of its occurrence is still not known. However, the cost penalty for equipment designed to completely avoid damaging vibration is modest and is almost always easily justified.

Some of the problem areas concerned with prediction of vibration include:
  1. the complex pattern of flow through a tube bundle
  2. the complicated fluid mechanics of a bank of vibrating tubes
  3. the role of damping
  4. the rates of wear and fatigue.
Nevertheless, it is possible to develop design criteria, especially when tempered with experience, to ensure that equipment will be safe from vibration damage.

Flow-induced vibrations problems in tubular equipment are commonly thought of as consisting entirely of mechanical failure of the tubes. However, the vibration can increase the shellside pressure drop, sometimes as much as double. Further, an acoustically vibrating unit can produce an intolerably high noise level. With an increasing emphasis on noise control, acoustic vibration must be an important consideration in design of tubular equipment.

Friday, March 27, 2009

Physical Properties in Evaporators

To calculate heat-transfer rates, physical-property data for the fluids being treated must be available. Physical property data should be as accurate as possible, especially as more accurate heat-transfer correlations become available. However, most physical properties of mixtures must be calculated or estimated; consequently there is little need to attempt to determine true film temperatures. Physical-property data at the average bulk fluid temperature are generally sufficient.

The following physical properties are usually required in order to obtain satisfactory calculated heat transfer rates:
  1. viscosity
  2. thermal conductivity
  3. density
  4. specific heat
  5. latent heat
  6. surface tension
When condensing or vaporizing over a temperature range, a curve representing heat load as a function of temperature should also be available. In addition, any concentration effects should be known.

Thursday, March 26, 2009

Types of Heat Transfer Operations

There are two types of heat transfer operation: sensible heat and change of phase. Sensible heat operations involve heating or cooling of a fluid in which the heat transfer results only in a temperature change of the fluid. Changeof-phase heat transfer results in a liquid being changed into a vapor or a vapor being changed into a liquid. Boiling or vaporization is the convection process involving a change in phase from liquid to vapor. Condensation is the convection process involving a change in phase from vapor to liquid. Many applications involve both sensible heat and change-of-phase heat transfer.

Sensible Heat Transfer Inside Tubes

Sensible heat transfer in most applications involves forced convection inside tubes or ducts or forced convection over exterior surfaces.

The heating and cooling of fluids flowing inside conduits are among the most important heat-transfer processes in engineering. The flow of fluids inside conduits may be broken down into three flow regimes. These flow regimes are measured by a ratio called the Reynolds number which is an indication of the turbulence of the flow inside the conduit. The three regimes are:

Laminar Flow Reynolds numbers less than 2,100
Transition Flow Reynolds numbers between 2,100 and 10,000
Turbulent Flow Reynolds numbers greater than 10,000